Operation of a domestic wastewater treatment plant
1. Filling
Initially, the wastewater enters a pre-treatment chamber (precipitator) where trapped contaminants are trapped. All incoming wastewater is collected in a precipitator until the start of the aeration phase.
2. Aeration
Through the contact pipe, a portion of the effluent enters the batch reactor. The reactor undergoes biological wastewater treatment with the help of so-called “activated sludge” – microorganism flakes. Wastewater is agitated (denitrification), aerated, and agitated (decomposition and nitrification of organic pollutants) at set intervals. To prevent excess activated sludge from forming in the batch reactor, a small amount is pumped back to the pre-treatment chamber. The sludge accumulated in the settler is disposed of during the maintenance of the device. If no new wastewater arrives within the next 6 hours, the treatment plant automatically switches to energy-saving mode.
3. Precipitation
Upon completion of the aeration, a two-hour dormant phase begins in the reactor. Activated sludge settles to the bottom and treated wastewater remains at the top of the reactor. During aeration, part of the activated sludge penetrates into the clean water pump and settles in it. To prevent sludge from entering the treated wastewater, the unit is equipped with a patented automatic flushing system that cleans the pump in three short pulses.
4. Release
n the discharge phase, treated water is pumped out of the unit. A new cleaning cycle is then started.
BASIC 1-16 |
---|
Number of inhabitants: |
1-16 |
Equipment kit: |
- Pump (for discharging clean water and returning excess sludge); - Aerator; - AQUAswitch level switch; - Control panel; - Sampling chamber. |
Installed in the tank: |
Buffle |
Features: |
Simple construction (only 2 electrical parts) |
CLASSIC Z 1-16 |
---|
Number of inhabitants: |
1-16 |
Equipment kit: |
- Clean water drain pump; - Pump (for discharging clean water and returning excess sludge); - Aerator; - AQUAswitch level switch; - Control panel; - Sampling chamber. |
Installed in the tank: |
On the chains |
Features: |
Possibility of use in new or existing containers. Adjustment of working volume according to suspension height. |
CLASSIC Z 17-50 |
---|
Number of inhabitants: |
17-50 |
Equipment kit: |
- Clean water drain pump; - Pump (for discharging clean water and returning excess sludge); - Aerator; - AQUAswitch level switch; - Control panel; - Sampling chamber. |
Installed in the tank: |
On the chains |
Features: |
Possibility of use in new or existing containers. Adjustment of working volume according to suspension height. |
AQUAmax BASIC and CLASSIC Z TECHNICAL PARAMETERS
Number of inhabitants | 4 | 6 | 8 | 12 | 16 |
---|---|---|---|---|---|
SNIGO volume (liters) | 3200 | 4600 | 6600 | 9000 | 12000 |
Length (mm) | 2400 | 2500 | 3500 | 4500 | 6000 |
Diameter (mm) | 1400 | 1700 | 1700 | 1700 | 1700 |
Weight (kg) | 190 | 2400 | 300 | 370 | 480 |
Height of shaft (mm) | 500-2500 (optionally) | ||||
Diameter of manhole (mm) | 600 |
AQUAmax for 20 – 50 inhabitants
Number of inhabitants | 20 | 24 | 28 | 32 | 36 | 40 | 44 | 48 |
---|---|---|---|---|---|---|---|---|
Number of tanks, vnt. | 2 | 2 | 2 | 2 | 3 | 3 | 1 | 3 |
SNIGO tank volume (liters) | 10000 | 12000 | 12000 | 12000 | 12000 | 10000 | 12000 | |
+6600 | +6600 | +10000 | +12000 | +6600 | +10000 | 44000 | +8700 | |
+GB | +GB | +GB |
Indicators of treated domestic wastewater
Standard | AQUAmax | |
---|---|---|
BOD(5) | 30 mg/l | 15 mg/l |
COD | 125 mg/l | 75 mg/l |
Suspended solids | 35 mg/l | 25 mg/l |
Total N | 20 mg/l | 10 mg/l |
Phosphorus | < 5 kb.m/d | < 5 kb.m/d |